<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Industrial sector Archives - TCR Advanced Engineering</title>
	<atom:link href="https://blog.tcradvanced.com/tag/industrial-sector/feed/" rel="self" type="application/rss+xml" />
	<link>https://blog.tcradvanced.com/tag/industrial-sector/</link>
	<description>Asset Integrity Management</description>
	<lastBuildDate>Mon, 23 May 2022 08:24:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.8</generator>

<image>
	<url>https://blog.tcradvanced.com/wp-content/uploads/2020/04/favicon.png</url>
	<title>Industrial sector Archives - TCR Advanced Engineering</title>
	<link>https://blog.tcradvanced.com/tag/industrial-sector/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Helium Leak Test: Techniques and Components</title>
		<link>https://blog.tcradvanced.com/helium-leak-test-techniques-and-components/</link>
		
		<dc:creator><![CDATA[TCR Media]]></dc:creator>
		<pubDate>Tue, 26 Apr 2022 10:12:52 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[asset integrity]]></category>
		<category><![CDATA[Helium Leak Test]]></category>
		<category><![CDATA[Industrial sector]]></category>
		<category><![CDATA[TCR Advanced]]></category>
		<guid isPermaLink="false">https://blog.tcradvanced.com/?p=8858</guid>

					<description><![CDATA[<p>The operations of industrial assets without interruption are possible through routine maintenance regulated by periodic non-destructive tests. In industry, most accidents occur due to leakage in components, causing loss and destruction. Helium Leak Test is a profound method of detecting leaks compared with pneumatic and hydro tests. It provides accurate test results in less time,...</p>
<p>The post <a href="https://blog.tcradvanced.com/helium-leak-test-techniques-and-components/">Helium Leak Test: Techniques and Components</a> appeared first on <a href="https://blog.tcradvanced.com">TCR Advanced Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-weight: 400">The operations of industrial assets without interruption are possible through routine maintenance regulated by periodic non-destructive tests. In industry, most accidents occur due to leakage in components, causing loss and destruction. <a href="https://www.tcradvanced.com/helium-leak-testing.html">Helium Leak Test</a> is a profound method of detecting leaks compared with pneumatic and hydro tests. It provides accurate test results in less time, and the chances of errors are minimal compared to other leak testing methods. The helium Leak Test is crucial for uninterrupted production.  </span></p>
<p><span style="font-weight: 400">Industrial facilities like </span><b>Chemical Plants, Power Plants and Oil &amp; Gas industries </b><span style="font-weight: 400">demand helium leak tests regularly.  Components and equipment in these sectors work 24/7 with highly sensitive elements which have a high potential for generating leakage. The timely inspection with Helium Leak Test can detain the risks of fatal accidents. </span><b> </b></p>
<p><span style="font-weight: 400">Industries that integrate the below-mentioned </span><b>components often need the <a href="https://www.tcradvanced.com/helium-leak-testing.html">Helium Leak Test</a></b><span style="font-weight: 400"> for regular intervention  &#8211; </span></p>
<ul>
<li style="font-weight: 400"><span style="font-weight: 400">Heat exchangers &amp; Condensers, Power Plant Turbines</span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Fugitive Emission of Valves, Manifold seals &amp; Bellows </span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Vacuum vessels and systems, Medical devices </span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Fuel lines &amp; Hydraulic lines, Radiators &amp; glove boxes, </span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Systems used in hazardous environments.</span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Vacuum furnaces &amp; vacuum coaters,  </span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Semiconductor process equipment</span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Laser process equipment &amp; Gas handling systems, </span></li>
<li style="font-weight: 400"><span style="font-weight: 400">Hermetically sealed packages, Liquid gas facilities &amp; Cryo tanks</span></li>
</ul>
<p><span style="font-weight: 400">Helium leak test is widely used in industry sectors such as </span><b>Petrochemical Industry, Manufacturing Industry, Pharmaceutical and Fertilizer.</b></p>
<p><b>Three Basic Techniques to perform <a href="https://www.youtube.com/watch?v=46fnkPFnoSs">Helium Leak Testing </a></b></p>
<p><span style="font-weight: 400">Process of helium leak detection changes as per the component’s characteristics. There are three methods to conduct helium leak tests that give precise results &#8211; </span><br />
<b></b></p>
<ol>
<li>
<h3><b>Sniffer Technique</b></h3>
</li>
</ol>
<div id="attachment_8866" style="width: 768px" class="wp-caption aligncenter"><img fetchpriority="high" decoding="async" aria-describedby="caption-attachment-8866" class=" wp-image-8866" src="https://blog.tcradvanced.com/wp-content/uploads/2022/04/Pressure-Testing-HLT-300x112.png" alt="HLT- Pressure Testing" width="758" height="283" srcset="https://blog.tcradvanced.com/wp-content/uploads/2022/04/Pressure-Testing-HLT-300x112.png 300w, https://blog.tcradvanced.com/wp-content/uploads/2022/04/Pressure-Testing-HLT-768x287.png 768w, https://blog.tcradvanced.com/wp-content/uploads/2022/04/Pressure-Testing-HLT.png 855w" sizes="(max-width: 758px) 100vw, 758px" /><p id="caption-attachment-8866" class="wp-caption-text">Pressure Testing is a technique for Helium Leak Detection</p></div>
<p><span style="font-weight: 400">This technique uses Helium as a tracer gas coordinating with instruments that help detect the presence of Helium in the environment. This method locates the leak by sniffing the possible leak path. Leaks that are detected in sniffer techniques can also be repaired. Sniffer Technique is not quantitative and requires an operator’s skill in determining leaks. Immense care has to be taken as sniffing is indicative at a level of 1×10-5 atm.mm3/sec. diluting Helium and exiting leak path due to significant air movement. The primary purpose of the sniffer technique is to elevate the internal pressure within the part of the above ambient. As Helium is in the internal volume, the sniffer probe identifies the source of leakage where the leak might exit.</span></p>
<ol start="2">
<li>
<h3><b> Vacuum Technique</b></h3>
</li>
</ol>
<div id="attachment_8867" style="width: 773px" class="wp-caption alignnone"><img decoding="async" aria-describedby="caption-attachment-8867" class=" wp-image-8867" src="https://blog.tcradvanced.com/wp-content/uploads/2022/04/Vacuum-technique-HLT--300x114.png" alt="HLT - Vacuum Test " width="763" height="290" srcset="https://blog.tcradvanced.com/wp-content/uploads/2022/04/Vacuum-technique-HLT--300x114.png 300w, https://blog.tcradvanced.com/wp-content/uploads/2022/04/Vacuum-technique-HLT--768x292.png 768w, https://blog.tcradvanced.com/wp-content/uploads/2022/04/Vacuum-technique-HLT-.png 854w" sizes="(max-width: 763px) 100vw, 763px" /><p id="caption-attachment-8867" class="wp-caption-text">Vacuum Testing is a technique for Helium Leak Detection</p></div>
<p><span style="font-weight: 400">This technique has the same set-up as the sniffer method. The only difference is that the Helium is sprayed on the component through a vacuum probe to search for possible leakage in the component. Helium passes through the passage on the test object connecting to the detector, indicating whether the leak is present in the area where the helium search gas is exposed.</span></p>
<p><span style="font-weight: 400">The tracer probe test is best used on seals, flange connections, weld seams and many more industrial assets. </span></p>
<ol start="3">
<li>
<h3><b> Hood Technique </b></h3>
</li>
</ol>
<p><span style="font-weight: 400">The Hood Technique includes covering the component with plastic before the test begins. The area between the component and the hood is filled with Helium from the search gas reservoir. The total outer surface of the component exposed to the Helium. Further, the Helium enters through all leaks present in the component detecting the total leak rate on the machine. The hood test is considered the best to examine small vessels.</span></p>
<p><span style="font-weight: 400">TCR Advanced is an expert in bifurcating the component’s requirements as per its configuration. Thus, never pick the less but the best asset integrity management services. Click on this link to explore our website &#8211; <a href="https://www.tcradvanced.com/">www.tcradvanced.com </a> </span></p>
<p>&nbsp;</p>
<p>The post <a href="https://blog.tcradvanced.com/helium-leak-test-techniques-and-components/">Helium Leak Test: Techniques and Components</a> appeared first on <a href="https://blog.tcradvanced.com">TCR Advanced Engineering</a>.</p>